Ethernet 100Base-T4
100Base-T4 uses all four pairs. 100Base-TX only uses two
pairs.
(At the network interface cards/hubs)
(На кабелеs)
RJ45 FEMALE разъём at the network interface cards/hubs.
RJ45 MALE разъём На кабелеs.
| Контакт |
Сигнал |
Описание |
| 1 |
TX_D1+ |
Tranceive Data+ |
| 2 |
TX_D1- |
Tranceive Data- |
| 3 |
RX_D2+ |
Receive Data+ |
| 4 |
BI_D3+ |
Bi-directional Data+ |
| 5 |
BI_D3- |
Bi-directional Data- |
| 6 |
RX_D2- |
Receive Data- |
| 7 |
BI_D4+ |
Bi-directional Data+ |
| 8 |
BI_D4- |
Bi-directional Data- |
Примечание: TX & RX are swapped on Hub's. Don't know about
Bi-directional data.
Опубликовал: Joakim Ogren, Kim Scholte
Источник: ?
Все комментарии присылайте Joakim Ogren.
Ethernet 10/100Base-T
Same connector and pinout for both 10Base-T and 100Base-TX.
(At the network interface cards/hubs)
(-р ърсхыхs)
RJ45 FEMALE Ёрч·+ь at the network interface cards/hubs.
RJ45 MALE Ёрч·+ь -р ърсхыхs.
| -юэЄръЄ |
-шуэры |
+яшёрэшх |
| 1 |
TX+ |
Tranceive Data+ |
| 2 |
TX- |
Tranceive Data- |
| 3 |
RX+ |
Receive Data+ |
| 4 |
n/c |
Not connected |
| 5 |
n/c |
Not connected |
| 6 |
RX- |
Receive Data- |
| 7 |
n/c |
Not connected |
| 8 |
n/c |
Not connected |
-Ёшьхўрэшх: TX & RX are swapped on Hub's.
+яєсышъютры: Joakim Ogren, Jeffrey R. Broido
+ёЄюўэшъ: ?
-ёх ъюььхэЄрЁшш яЁшё_ырщЄх Joakim Ogren.
AUI
Is the directions right???
(At the Ethernet card)
15 PIN D-SUB FEMALE at the Ethernet card.
| Контакт |
Описание |
| 1 |
control in circuit shield |
| 2 |
control in circuit A |
| 3 |
data out circuit A |
| 4 |
data in circuit shield |
| 5 |
data in circuit A |
| 6 |
voltage common |
| 7 |
? |
| 8 |
control out circuit shield |
| 9 |
control in circuit B |
| 10 |
data out circuit B |
| 11 |
data out circuit shield |
| 12 |
data in circuit B |
| 13 |
voltage plus |
| 14 |
voltage shield |
| 15 |
? |
Опубликовал: Joakim Ogren
Источник: Tommy's pinout Collection
by Tommy Johnson
Все комментарии присылайте Joakim Ogren.
Сайт создан в системе uCoz
|